These production systems are completely different.
With a RAS water quality monitoring is intensive, as is the system.
A RAS is expensive to operate, and has an extremely high potential to have a failure that can result in high stock losses.
Ponds are more forgiving allowing more time to respond to any issue.
Think of it like the shock absorber in a car.
The longer the shock absorber, the rougher terrain the vehicle can be used on. This is a pond.
There is more time to respond to an issue.
A short shock absorber can only handle small bumps. That is a RAS.
A small issue in a RAS needs a rapid response.
The key to any production system is regular water quality monitoring and keeping complete records.
It doesn't really matter what the production system is, pond or RAS
You need to be aware of the limitations of whatever you are growing fish in.
You need to get an understanding about each unit's personality.
Ponds are particularly prone to individual personalities.
Monitoring water and keeping records is like being a psychiatrist and analysing a person's behaviour traits.
This way you can build a behaviour pattern so you can make predictions and make adjustments before anything becomes a problem.
Ponds should have water samples taken from several points.
The larger the pond the more monitoring points.
It is particularly probable that a large pond can have oxygen low points.
With a pond that has a regular, or constant water flow this is more important.
Dead spots can be more likely.
Also it is important to determine how much water flow/exchange is necessary.
This will help with understanding what the stocking densities should/could be.
Building knowledge of the water quality is how to determine the stocking density.
NO SUCH thing as "how many fish can I put in this system/pond."
It's about the system, and the operator.
Raising Australian perch larvae in a pond can't compare to a RAS.
The cost of raising larvae in a RAS is high in the extreame compared to a pond due to the cost of food production for the larvae.
Plankton production in a properly managed plankton pond is almost free.
To produce fry in a plankton pond is only a few cents each. (Less than au10 cents each.)
SUMMARY
Oxygen is critical and must be constantly monitored.
Ammonia is the next most important parameter to be highly vigilant to.
A RAS must have VERY GOOD monitoring systems.
The best would be a system that sends text messages to several people when there is a problem.
There should also be a battery powered alarm system with a LOUD alarm that can be heard at any time by people at the site.
There should always be someone on site, 24/7 to respond to an alarm.
There should always be someone available to be on site to attend to a failure within a few minutes.
(Depending how long the fish will survive, this may be as little as 5 minutes.)
Staff need to be well trained to respond to whatever reason has activated the alarm.
A RAS is expensive to operate. Electricity is usually the highest cost.
Labour is usually the next highest cost.
For ponds, there is usually no need for an alarm system, depending on stocking density.
If the stocking density is very high, an alarm may be necessary should the aeration system fail.
More critical at night when photosynthesis is consuming oxygen.
Stocking densities are much lower allowing plenty of time to respond to any issue.
I like to compare a RAS and a pond to watching a video.
A pond is the slow motion version of a RAS which is playing at more than double normal speed.
NOTE: For information about integrated filling and draining of ponds contact me directly for my new design.
- Less pipes half the quantity of pipes = less financial out lay.
- Auto maintenance of surface level
- Less overflow screen blockage
You can also use the website search tool at the bottom of each page
OTHER SPECIES